Net2 plus 1 door controller 12V 2A PSU Plastic cabinet
Box contents
| |
Connector - 2 way plug UL |
| |
Fasteners - 15mm PCB spacer 1.6mm board |
| |
Fitting kit - RS485/232 or TCP/IP comms converter |
| |
Fitting kit - ACU with PSU in cabinets & housings |
| |
Label - 682-531 ratings label |
| |
Label - product serial number label 27x10mm |
| |
Label - Tech support international |
| |
Label - Void if seal is broken, 80x30mm |
| |
Sales Code label, 27x20mm, Paxton EU, CE |
| |
Net2 Plus access control unit V2 |
| |
Cable tie Large |
| |
Net2 plus wiring labels with 17 light guides |
| |
2A PSU plastic cabinet assembly |
| |
2A PSU in plastic housing |
| Specifications - Net2 plus 1 door controller - 12V 2A PSU, Plastic cabinet |
| |
min |
typ |
max |
units |
| Electrical |
| Voltage supplied by Paxton 2A PSU |
13 |
13.8 |
14 |
V DC |
| Current capacity of Paxton 2A PSU |
|
|
2000 |
mA |
| Operating voltage |
11 |
|
24 |
V DC (+20%) |
| Current consumption |
|
|
200 |
mA |
| Switchable current |
|
|
4 |
A |
| Switchable voltage |
|
|
24 |
V DC (+20%) |
| Alarm output current |
|
|
1 |
A @ 12 V DC |
| Environment |
| Operating temperature - Battery limits |
0 |
|
45 |
°C |
| Moisture resistance |
|
None |
|
|
| System Specification |
| Max number of ACUs per system |
|
|
1000 |
|
| Number of card holders |
|
|
50000 |
|
| Number of PINs |
|
|
50000 |
|
| PIN length |
4 |
|
8 |
digits |
| Number of codes |
|
|
50 |
|
| Code length |
4 |
|
8 |
digits |
| Readers/keypads per door |
|
|
2 |
per port |
| Door open time |
1 |
7 |
999999 |
sec |
| Time zones |
|
|
64 |
|
| Individual times within a time zone |
|
|
2000 |
|
| Number of events stored on ACU |
|
|
2728 |
|
| Data retention during power loss |
30 |
|
|
day(s) |
| Can be used with fail OPEN release |
|
Yes |
|
|
| Can be used with fail CLOSED release |
|
Yes |
|
|
| Exit button input |
|
Yes |
|
|
| Door contact input |
|
Yes |
|
|
| Alarm/bell output |
|
Yes |
|
|
| PSU monitoring input |
|
Yes |
|
|
| Tamper input |
|
Yes |
|
|
| Intruder alarm integration input |
|
Yes |
|
|
| Wiring |
| Reader cable type |
|
Belden 9540 |
|
|
| RS485 data line |
|
CAT5 or Belden 8723 |
|
|
| Max RS485 data line length |
|
|
1000 |
m |
| Max number of ACU's per RS485 data line |
|
|
200 |
|
| TCP/IP connection |
|
Yes |
|
|
| Max TCP/IP nodes |
|
|
200 |
|
| Ethernet network speed |
10 |
|
100 |
Mbps |
| Ethernet bandwidth required |
9 |
115 |
200 |
kbps |
| DHCP support |
|
Yes (static IP recommended |
|
|
| Modem support |
|
Yes |
|
|
| Dimensions - Control unit |
| Width |
|
116 |
|
mm |
| Height |
|
126 |
|
mm |
| Depth |
|
25 |
|
mm |
| Dimensions - 2A PSU in plastic cabinet |
| Width |
|
232 |
|
mm |
| Height |
|
320 |
|
mm |
| Depth |
|
80 |
|
mm |